SLEEKFENCE™ Project Application Chart

  • These structural calculations are strictly based on SLEEKFENCE™ systems, and Canadian requirements.
  • PSF & Estimated Windload ratings are based on our max screw distances being adhered to when mounting panels to posts, and it assumes posts are securely mounted/set in ground.
  • Ratings for in ground applications are assuming posts are set below the frost line, with concrete. Structural engineering is recommended on a per project basis, to determine the best footing design (width, depth, and cement type).
  • Ratings for concrete mount posts are assuming posts are securely fastened – structural engineering is also recommended on a per project basis, to determine the best anchor size and type.
  • Guard Rails, Balcony Railing, and Pool Fencing requirements may vary per application. This is a general guide, and structural engineering is required on a per project basis, to determine post mounting method for your project.

Fence Height & Panel Type

Max Screw distance – ALL APPLICATIONS*
When mounting panels to posts with SLEEKFENCE™ screws as specified in our installation guide.
Estimated Max Wind Speed (MPH/KMH) IN GROUND*
When posts are set securely in the ground below frost line, in engineer approved concrete footings.
Estimated Max Wind Speed (MPH/KMH) CONCRETE MOUNT*
When posts are mounted on cured, engineered concrete walls securely, utilizing factory baseplates and engineer approved anchors.
Guardrail / Balcony Railing Applications*
When installed beside a drop off greater than 4′, and / or decks or balconies up to a maximum of 4 stories high.
Pool Fencing Applications*
46″ high fencing must be installed with a 2-3″ gap under the fence in order to meet minimum height requirement of 48″ for pool fencing.

46″ High
Privacy Fence

18″ On Center

107mph / 172kmh
With Post Depth at 3′

48mph / 78kmh

MEETS REQUIREMENTS
(combination of 6psf windload and 1/2 guardload

MEETS REQUIREMENTS
(combination of 6.5psf windload and 1/2 guardload

69″ High
Privacy Fence

18″ On Center

99mph / 159kmh
With Post Depth at 3-4′

43.5mph / 70kmh

MEETS REQUIREMENTS
(combination of 5psf windload and 1/2 guardload

MEETS REQUIREMENTS
(combination of 5.5psf windload and 1/2 guardload

93″ High
Privacy Fence

16″ On Center

98mph / 157kmh
With Post Depth at 5′

DOES NOT MEET
REQUIREMENTS

DOES NOT MEET
REQUIREMENTS

DOES NOT MEET
REQUIREMENTS

115″ High
Privacy Fence

16″ On Center

55mph / 88kmh
With Post Depth at 5-6′

DOES NOT MEET
REQUIREMENTS

DOES NOT MEET
REQUIREMENTS

DOES NOT MEET
REQUIREMENTS

46″ High
Screen Fence

18″ On Center

123mph / 197kmh
With Post Depth at 3′

51mph / 83kmh

MEETS REQUIREMENTS
(combination of 6.9psf windload and 1/2 guardload

MEETS REQUIREMENTS
(combination of 7.4psf windload and 1/2 guardload

69″ High
Screen Fence

18″ On Center

113mph / 181kmh
With Post Depth at 3-4′

46.7mph / 75kmh

MEETS REQUIREMENTS
(combination of 5.75psf windload and 1/2 guardload

MEETS REQUIREMENTS
(combination of 6.35psf windload and 1/2 guardload

93″ High
Screen Fence

16″ On Center

112mph / 180kmh
With Post Depth at 5′

DOES NOT MEET
REQUIREMENTS

DOES NOT MEET
REQUIREMENTS

DOES NOT MEET
REQUIREMENTS

115″ High
Screen Fence

16″ On Center

63mph / 101kmh
With Post Depth at 5-6′

DOES NOT MEET
REQUIREMENTS

DOES NOT MEET
REQUIREMENTS

DOES NOT MEET
REQUIREMENTS

Please don’t hesitate to CONTACT US if you have any questions about this report, or your project application. We will accept no responsibility for failure of our SLEEKFENCE™ systems in the event this application chart and/or our recommendations are not followed, or winds greater than ratings listed have caused damage or failure to our products.